Discussion:
VVX 500 MWI not working...
Philippe Laurent
2012-08-09 16:18:18 UTC
Permalink
If anyone out there is running VVX 500 devices on their SipX deployments,
and has actually been able to get MWI working, I would very much like to
know how. An IP650 on the same server, connecting to the same account,
shows the MWI just fine.

SipX: 4.4, patched
VVX 500: Firmware release 4.02.

Many thanks in advance for your time.
Todd Hodgen
2012-08-09 20:39:38 UTC
Permalink
You have to run the 4.0.2 firmware, as there was a bug 4.0.1 that affected
these phones working with sipxecs.



Some features will only work if you provision the phone via TFTP, and not
via the GUI. Music-on-hold is one of those features.



What I've done is configured the 000000000000.cfg file to look for vvx500
files in a separated vv500 directory. We have a standard config file we
use, which we edit and place in that directory. We edit it for the correct
mac, and add the username/password in the file. We then reboot the phone,
it retrieves it's config file from that directory and MOH and MWI both work.



If you need some sample files, let me know and I can forward them to you.



From: sipx-users-***@list.sipfoundry.org
[mailto:sipx-users-***@list.sipfoundry.org] On Behalf Of Philippe
Laurent
Sent: Thursday, August 09, 2012 9:18 AM
To: sipx-users
Subject: [sipx-users] VVX 500 MWI not working...



If anyone out there is running VVX 500 devices on their SipX deployments,
and has actually been able to get MWI working, I would very much like to
know how. An IP650 on the same server, connecting to the same account, shows
the MWI just fine.



SipX: 4.4, patched

VVX 500: Firmware release 4.02.



Many thanks in advance for your time.
Philippe Laurent
2012-08-09 20:52:27 UTC
Permalink
Todd -

I would very much appreciate those sample files!

Many thanks for the input...

Philippe
Post by Todd Hodgen
You have to run the 4.0.2 firmware, as there was a bug 4.0.1 that affected
these phones working with sipxecs.****
** **
Some features will only work if you provision the phone via TFTP, and not
via the GUI. Music-on-hold is one of those features.****
** **
What I’ve done is configured the 000000000000.cfg file to look for vvx500
files in a separated vv500 directory. We have a standard config file we
use, which we edit and place in that directory. We edit it for the correct
mac, and add the username/password in the file. We then reboot the phone,
it retrieves it’s config file from that directory and MOH and MWI both work.
****
** **
If you need some sample files, let me know and I can forward them to
you. ****
** **
*Sent:* Thursday, August 09, 2012 9:18 AM
*To:* sipx-users
*Subject:* [sipx-users] VVX 500 MWI not working...****
** **
If anyone out there is running VVX 500 devices on their SipX deployments,
and has actually been able to get MWI working, I would very much like to
know how. An IP650 on the same server, connecting to the same account,
shows the MWI just fine.****
** **
SipX: 4.4, patched****
VVX 500: Firmware release 4.02.****
** **
Many thanks in advance for your time.****
_______________________________________________
sipx-users mailing list
List Archive: http://list.sipfoundry.org/archive/sipx-users/
Kyle Haefner
2012-08-10 14:33:07 UTC
Permalink
Hi Todd,

Anyway you can but these up on the wiki? I can also do it if you
attach the files.

Kyle
Post by Todd Hodgen
You have to run the 4.0.2 firmware, as there was a bug 4.0.1 that affected
these phones working with sipxecs.
Some features will only work if you provision the phone via TFTP, and not
via the GUI. Music-on-hold is one of those features.
What I’ve done is configured the 000000000000.cfg file to look for vvx500
files in a separated vv500 directory. We have a standard config file we
use, which we edit and place in that directory. We edit it for the correct
mac, and add the username/password in the file. We then reboot the phone,
it retrieves it’s config file from that directory and MOH and MWI both work.
If you need some sample files, let me know and I can forward them to you.
Laurent
Sent: Thursday, August 09, 2012 9:18 AM
To: sipx-users
Subject: [sipx-users] VVX 500 MWI not working...
If anyone out there is running VVX 500 devices on their SipX deployments,
and has actually been able to get MWI working, I would very much like to
know how. An IP650 on the same server, connecting to the same account, shows
the MWI just fine.
SipX: 4.4, patched
VVX 500: Firmware release 4.02.
Many thanks in advance for your time.
--
Kyle Haefner, M.S.
Communication Systems Programmer
Colorado State University
Fort Collins, CO
Phone: 970-491-1012
Email: ***@colostate.edu

01010010 01100101 01100001 01101100 00100000 01101101 01100101
01101110 00100000 01110000 01110010 01101111 01100111 01110010
01100001 01101101 00100000 01101001 01101110 00100000 01100010
01101001 01101110 01100001 01110010 01111001 00101110
Loading...